LIR-LARM is a module for analysis and design of the separate reinforced concrete bar or plate element according to appropriate building code. Design model of the element and loads applied to this element can be either imported from
LIR-ARM module or defined in stand-alone mode. Areas of reinforcement are determined and then the specified reinforcement is checked for selected element.
LIR-LARM module contains tools that help you define and edit section parameters, material properties, forces and their unfavourable combinations.
LIR-LARM module also contains extensive Help system where you can find information about options and tools of the module.
The following building codes are supported:
− SNIP 2.03.01-84;
− TSN-100;
− DSTU 3760-98;
− SNIP 52-01-2003;
− Eurocode 2 (according to ultimate limit states only).